FXS Line Testing

You can test FXS telephone lines that are connected to the device's FXS ports. The test is done per FXS port and FXS country coefficient type - USA (70) or TBR21 (66). The results of the test are sent to syslog and includes various line statuses and electrical line measurements, for example:

Hazardous Potential Tests (HPT) - hazardous AC or DC voltage is present on the tip and ring or both.
Foreign Electromotive Force Tests (FEMT) - foreign voltage is present on the tip, ring or both
Resistive Fault Tests (RFT) - tip or ring is shorted to ground, or they are shorted to each other
Receiver Off-hook Tests (ROH) - one or more phones are off hook on phone line during test.
Ringer Impedance Tests (RIT)
AC/DC line voltage
AC/DC line current
Line resistance
Line capacity
Hook status (on or off)
Message Waiting Indication (MWI) status (on or off)
Ring status (on or off)
Reversal polarity status (on or off)
FXS line testing is supported only by the FXS module type that supports outdoor FXS cabling.
You can only test one FXS port at a time.
Don’t start a new test if one is still running.
Each new test overwrites the previous test results.
The FXS port interface is out of service (OOS) during the test.
Make sure that a telephone is connected to the FXS port that you want to test and that the telephone is in on-hook state and not servicing any calls.
To run the FXS line test:
1. Access the VoIP command set:
# configure voip
2. Access the FXS interface command set:
(config-voip)# interface fxs-fxo
3. Type the following command:
(fxs-fxo)# fxs-line-testing < Module/Port > {66|70}

For example, to test FXS port 4 on FXS module1 with coefficient type USA:

(fxs-fxo)# fxs-line-testing 1/4 70

Line Testing on FXS Port 4 in Module 1 is Executing... Please wait a few seconds.